Position首頁 > Home > Safety products > Safety interlock switch > Electromagnetic locking door lock
D3SL-T/RFID electromagnetic locking type
1.png

·Electromagnetic force locking 500N

·Adopt a small plane "electromagnetic" locking structure.

·Support 16 to 20 cascaded connections.

·Design of permanent magnet in matcher

·Small body, simple installation

·Full-angle eye-catching indicator light

·No abrasive powder will be produced.

·IP65/IP67 protection


D3SL-T/RFID Series Selection Table

Locking mode

deploy

model

Output mode

coded system

Electromagnetic locking

normalized form

D3SL-T-DB-N2

NPN

universal coding

D3SL-T-DB-N1

NPN

Unique coding

D3SL-T-DB-P2

PNP

universal coding

D3SL-T-DB-P1

PNP

Unique coding

Advanced type

D3SL-T-DG-N2

NPN

universal coding

D3SL-T-DG-N1

NPN

Unique coding

D3SL-T-DG-P2

PNP

universal coding

D3SL-T-DG-P1

PNP

Unique coding


Technical parameters of D3SL-T/RFID

type

Hinged door

small-sized

M12 connector

normalized form

High functional type

working distance

Sao(off-0n)

4mm

Sar(on-0ff)

4mm

Response time

Lock → release

155ms

Release → lock

155ms

Detection → Non-detection

20ms+2ms* (Number of cascaded connections -1)

Non-detection → detection

300ms+25ms* (Number of cascaded units -1)

Control output

(OSSD output)

Output mode

Transistor output "2

Maximum load current

150mA

Residual voltage (on)

Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

OFF voltage

Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

leakage current

Up to 0.5mA

Maximum load capacity

0.8uF

Load connection resistance

Max. 2.5 Euro

AUX output

(Non-safety system output)

Output mode

Transistor output

Maximum load current

50mA

Residual voltage (ON)

Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

external input

(Short-circuit current)

Safety input

About 1.5 max 2

Locking control input OSSD action switching input

About 2.5 mA

Reset /EDM input

About 5mA (high functional type only)

EDM select input

About 2.5 mA (high functional type only)

Power Supply 

Power supply voltage

24 VDC 10% including ripple (P-P)10% Class2

consumed power

<5W

protective circuit

Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

Environmental resistance

Enclosure protection grade

IP65/67(IEC60529)

Operating ambient temperature

20 degrees below zero to 55 degrees without freezing.

Storage ambient temperature

25 degrees below zero to 70 degrees without freezing.

Using ambient humidity

5% to 95%RH

Storage environment humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

Applicable standards

ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


Model description of safety switch

 1728548977520914.png 



hookup

Standard type (NPN, cascade)

Standard (PNP, cascade)

1719978292858022.png

Standard type (NPN, cascade)

1719978426648983.png

Standard (PNP, cascade)

1719978725470017.png

Functional (NPN, cascade)

Functional (PNP, cascade)

1719979076106539.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

High functional type (NPN, cascade)

1719979521976024.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

Functional (PNP, cascade)

1719979875434469.png

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

S: reset switch

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

*1. Make ?EDM and reset: wire as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch


Indication of indicator light

1719983442751425.png


Product ruler diagram

1719983681983392.png


Selection Method of Safety Switch D3SL-T/RFID Series

1728618489514684.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 黄色视频在线观看www | 91丨国产丨白浆秘 冰块 | 人人操人人干777色狠狠俺去了 | 男人的天堂AV大香蕉 | 人妻不卡的中文字幕视频在线 | 日韩狼友视频在线观看 | 极品车模A片在线观看 | 搡老熟女老女人的阴户 | AV一区二区三区四 | 寡妇亲子伦一区二区三区四区 | 蜜桃一区二区三区 | 成人无码区免费A片久久鸭软件 | WWw.C0m黄色电影 | 午夜福利一二三区 | 91黄色视频在线播放 | 又黑又粗又长91 | 7M人妻内射视频 | 成人国精品秘 在线观看 | 丰满人妻被猛烈进入中文字幕四川 | 日韩无码不卡视频 | 日本黑人一区二区免费视频 | 在线观看免费高清完整版成人 | av在线免费播放 | 91亚洲精品久久久蜜桃 网站 | 欧美日韩一区在线 | 第一中文字幕在线观看 | 免费看黃色AAAAAA 片 | 专干老熟女300部 | 国产伦精品一区二区三区视频免费 | 强奸乱伦小说一区二区 | 无码人妻久久中文一区二区 | 午夜成人高清在线 | 国产老熟女伦老熟妇A片小川桃果 | 一品道在线毛片观看 | 免费看无码一级A片放24小时 | 免费国产凹凸在线视频 | 国产系列精品AV | 日韩熟女一区二区 | 无码精品一区二区三区潘金莲 | 麻豆精品国产熟妇aⅴ一区 www.高清无码在线观看 | 少妇搡BBBB搡BBB搡毛片 |