亚洲精品久久国产高清小说_日韩欧美不卡成人中文字幕_亚洲精品456在线播放乱码_精品亚洲国产成人A_黄色大片一级黄色_蜜臀av福利无码一二三_免费激情视频网站_日韩高清在线观看免费_欧美 日韩 三级在线看_先锋影音男人资源

Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Safety products > Safety interlock switch > Electromagnetic locking door lock
D3SL-T/RFID electromagnetic locking type
1.png

·Electromagnetic force locking 500N

·Adopt a small plane "electromagnetic" locking structure.

·Support 16 to 20 cascaded connections.

·Design of permanent magnet in matcher

·Small body, simple installation

·Full-angle eye-catching indicator light

·No abrasive powder will be produced.

·IP65/IP67 protection


D3SL-T/RFID Series Selection Table

Locking mode

deploy

model

Output mode

coded system

Electromagnetic locking

normalized form

D3SL-T-DB-N2

NPN

universal coding

D3SL-T-DB-N1

NPN

Unique coding

D3SL-T-DB-P2

PNP

universal coding

D3SL-T-DB-P1

PNP

Unique coding

Advanced type

D3SL-T-DG-N2

NPN

universal coding

D3SL-T-DG-N1

NPN

Unique coding

D3SL-T-DG-P2

PNP

universal coding

D3SL-T-DG-P1

PNP

Unique coding


Technical parameters of D3SL-T/RFID

type

Hinged door

small-sized

M12 connector

normalized form

High functional type

working distance

Sao(off-0n)

4mm

Sar(on-0ff)

4mm

Response time

Lock → release

155ms

Release → lock

155ms

Detection → Non-detection

20ms+2ms* (Number of cascaded connections -1)

Non-detection → detection

300ms+25ms* (Number of cascaded units -1)

Control output

(OSSD output)

Output mode

Transistor output "2

Maximum load current

150mA

Residual voltage (on)

Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

OFF voltage

Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

leakage current

Up to 0.5mA

Maximum load capacity

0.8uF

Load connection resistance

Max. 2.5 Euro

AUX output

(Non-safety system output)

Output mode

Transistor output

Maximum load current

50mA

Residual voltage (ON)

Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

external input

(Short-circuit current)

Safety input

About 1.5 max 2

Locking control input OSSD action switching input

About 2.5 mA

Reset /EDM input

About 5mA (high functional type only)

EDM select input

About 2.5 mA (high functional type only)

Power Supply 

Power supply voltage

24 VDC 10% including ripple (P-P)10% Class2

consumed power

<5W

protective circuit

Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

Environmental resistance

Enclosure protection grade

IP65/67(IEC60529)

Operating ambient temperature

20 degrees below zero to 55 degrees without freezing.

Storage ambient temperature

25 degrees below zero to 70 degrees without freezing.

Using ambient humidity

5% to 95%RH

Storage environment humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

Applicable standards

ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


Model description of safety switch

 1728548977520914.png 



hookup

Standard type (NPN, cascade)

Standard (PNP, cascade)

1719978292858022.png

Standard type (NPN, cascade)

1719978426648983.png

Standard (PNP, cascade)

1719978725470017.png

Functional (NPN, cascade)

Functional (PNP, cascade)

1719979076106539.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

High functional type (NPN, cascade)

1719979521976024.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

Functional (PNP, cascade)

1719979875434469.png

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

S: reset switch

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

*1. Make ?EDM and reset: wire as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch


Indication of indicator light

1719983442751425.png


Product ruler diagram

1719983681983392.png


Selection Method of Safety Switch D3SL-T/RFID Series

1728618489514684.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 精品国产一区二区在线观看 | 搡六十70老女人老熟女视频 | 国产乱老熟妇吃嫩草成人网站 | 亚洲美女被猛烈地操 | 免费国产凹凸在线视频 | 波多野结衣 无码 在线观看 | 18禁美女黄网站色大片免费看 | 亚洲成人av一区二区三区 | 中文字幕一二三四区 | 中文字幕av亚洲精品一部二部 | 在线观看中文AV一区 | 少妇看A片自慰免费蜜臀 | 亚洲天堂AV在线 | 精品国偷自产一区二区三区 | 精品高潮呻吟久久AV | 色情脫衣舞在线观看视频 | 六安精品国产乱码久久久久久 | 极品丰满少妇一级毛片 | 中文字幕一区二区三区四区五区 | 亚洲爆乳一区二区 | 羞羞 的视频 国产 一级 | 国产精品美女久久久久久久17.c | 艳妇臀荡乳欲伦无码豪妇荡乳 | 国产精品无码一二三区色情游戏 | 免费黄色视频观看 | 国产又粗又猛又爽又黄的视频在线观看 | 欧美午夜理伦三级在线观看 | 欧美性爱xxyxx | 女人自慰免费观看网站 | 淫乱无码一级久久片片红桃蜜桃亚洲精品 | 亚洲揄拍窥拍久久国产自揄拍 | 性少妇XXXX另类 | 台湾成人午夜福利电影 | 国产综合AV一区二区三区 | 亚洲午夜免费视频 | 丰满艳妇—8MAV | 波多野结衣AV网站免费观看 | 91久久婷婷国产麻豆精品电影 | 国产一级精品绿帽视频 | 经久久久久经久久久久经 | 国产a一级毛片爽爽影院无码 |